TY - JOUR
T1 - The effects of additional hollow cylinder coated to external fixator screws for treating pilon fracture
T2 - A biomechanical perspective
AU - Ramlee, Muhammad Hanif
AU - Gan, Hong Seng
AU - Ros Felip, Antonio
AU - Abdul Kadir, Mohammed Rafiq
N1 - Publisher Copyright:
© 2021 Elsevier Ltd
PY - 2021/8
Y1 - 2021/8
N2 - An external fixator is a promising medical device that could provide optimum stability and reduce the rate of complications in treating bone fracture during intervention period. It is noted that the biomechanics behaviour of device can be altered by introducing more features such as material suitability and additional components. Therefore, this study was conducted via finite element method to investigate the effects of additional hollow cylinder coated with external fixator screws in treating Type III pilon fracture. Finite element models which have been validated with experimental data were used to simulate stresses at the pin-bone interface and relative micromovement at interfragmentary fractures during swing (70 N load) and stance phases (350 N load). All bones and external fixators were assigned with isotropic material properties while the cartilages were simulated with hyper-elastic. For the hollow cylinder, polyethylene was assigned due to its properties which are equivalent to the bone. From the results, it is found that stresses at the pin-bone interface for the coated screws were reduced to 54% as compared to the conventional fixator. For the micromovement, there was no difference between both models, whereby the value was 0.03 mm. The results supported previously published literature, in which high stresses are unavoidable at the interface, fortunately, those stresses did not exceed the ultimate strength of bone, which is safe for treating patients. In conclusion, if patients are allowed to bear weight bearing, the external fixator with coated screws is a more favourable option to be fixed into the bone to avoid complications at the interface.
AB - An external fixator is a promising medical device that could provide optimum stability and reduce the rate of complications in treating bone fracture during intervention period. It is noted that the biomechanics behaviour of device can be altered by introducing more features such as material suitability and additional components. Therefore, this study was conducted via finite element method to investigate the effects of additional hollow cylinder coated with external fixator screws in treating Type III pilon fracture. Finite element models which have been validated with experimental data were used to simulate stresses at the pin-bone interface and relative micromovement at interfragmentary fractures during swing (70 N load) and stance phases (350 N load). All bones and external fixators were assigned with isotropic material properties while the cartilages were simulated with hyper-elastic. For the hollow cylinder, polyethylene was assigned due to its properties which are equivalent to the bone. From the results, it is found that stresses at the pin-bone interface for the coated screws were reduced to 54% as compared to the conventional fixator. For the micromovement, there was no difference between both models, whereby the value was 0.03 mm. The results supported previously published literature, in which high stresses are unavoidable at the interface, fortunately, those stresses did not exceed the ultimate strength of bone, which is safe for treating patients. In conclusion, if patients are allowed to bear weight bearing, the external fixator with coated screws is a more favourable option to be fixed into the bone to avoid complications at the interface.
KW - Biomechanics
KW - Coated screws
KW - Delta external fixator
KW - Micromovement
KW - Pilon fractures
KW - Synthetic bone
UR - http://www.scopus.com/inward/record.url?scp=85102867718&partnerID=8YFLogxK
U2 - 10.1016/j.injury.2021.03.017
DO - 10.1016/j.injury.2021.03.017
M3 - Article
C2 - 33745700
AN - SCOPUS:85102867718
SN - 0020-1383
VL - 52
SP - 2131
EP - 2141
JO - Injury
JF - Injury
IS - 8
ER -