TY - JOUR
T1 - Simple, rapid and sensitive detection of Parkinson's disease related alpha-synuclein using a DNA aptamer assisted liquid crystal biosensor
AU - Yang, Xiuxiu
AU - Zhao, Xiaofang
AU - Liu, Fengwei
AU - Li, Haiyu
AU - Zhang, Claire Xi
AU - Yang, Zhongqiang
N1 - Publisher Copyright:
© 2021 The Royal Society of Chemistry.
PY - 2021/5/14
Y1 - 2021/5/14
N2 - Alpha-synuclein (αS) has been proposed as a potential biomarker for the diagnosis of Parkinson's disease (PD). However, the detection of αS using a simple, rapid and sensitive approach is still challenging. Herein, we construct a new type of biosensor for the detection of αS, combining the stimuli-responsiveness of liquid crystals (LCs) and the specific interaction of a DNA aptamer with proteins. In principle, the positively charged surfactant hexadecyltrimethylammonium bromide (CTAB) binds with the negatively charged DNA aptamer via electrostatic interactions; in the presence of αS, the DNA aptamer specifically binds with αS and releases CTAB, which is an amphiphilic molecule and subsequently assembles at the LC-aqueous interface, resulting in a homeotropic alignment of LCs with a dark optical signal. In the absence of αS, CTAB binds with the DNA aptamer without affecting the alignment of LCs, which shows planar anchoring with a bright optical signal. The response time of LCs towards αS is rapid and can be down to minutes. The LC biosensor established here has a good specificity for αS and can recognize αS even from a mixture of proteins. The LC biosensor also exhibits high sensitivity with a limit of detection of αS as low as 10 pM, which is comparable to that of the enzyme-linked immunosorbent assay. This work provides a new strategy for the detection of αS in a simple, rapid and sensitive manner, possessing promising potentials towards early diagnosis and clinical applications.
AB - Alpha-synuclein (αS) has been proposed as a potential biomarker for the diagnosis of Parkinson's disease (PD). However, the detection of αS using a simple, rapid and sensitive approach is still challenging. Herein, we construct a new type of biosensor for the detection of αS, combining the stimuli-responsiveness of liquid crystals (LCs) and the specific interaction of a DNA aptamer with proteins. In principle, the positively charged surfactant hexadecyltrimethylammonium bromide (CTAB) binds with the negatively charged DNA aptamer via electrostatic interactions; in the presence of αS, the DNA aptamer specifically binds with αS and releases CTAB, which is an amphiphilic molecule and subsequently assembles at the LC-aqueous interface, resulting in a homeotropic alignment of LCs with a dark optical signal. In the absence of αS, CTAB binds with the DNA aptamer without affecting the alignment of LCs, which shows planar anchoring with a bright optical signal. The response time of LCs towards αS is rapid and can be down to minutes. The LC biosensor established here has a good specificity for αS and can recognize αS even from a mixture of proteins. The LC biosensor also exhibits high sensitivity with a limit of detection of αS as low as 10 pM, which is comparable to that of the enzyme-linked immunosorbent assay. This work provides a new strategy for the detection of αS in a simple, rapid and sensitive manner, possessing promising potentials towards early diagnosis and clinical applications.
UR - http://www.scopus.com/inward/record.url?scp=85105864867&partnerID=8YFLogxK
U2 - 10.1039/d1sm00298h
DO - 10.1039/d1sm00298h
M3 - Article
C2 - 33889925
AN - SCOPUS:85105864867
SN - 1744-683X
VL - 17
SP - 4842
EP - 4847
JO - Soft Matter
JF - Soft Matter
IS - 18
ER -