TY - JOUR
T1 - Mixing enhancement through a micromixer using topology optimization
AU - Dehghani, Tohid
AU - Sadegh Moghanlou, Farhad
AU - Vajdi, Mohammad
AU - Shahedi Asl, Mehdi
AU - Shokouhimehr, Mohammadreza
AU - Mohammadi, Mohsen
N1 - Publisher Copyright:
© 2020
PY - 2020/9
Y1 - 2020/9
N2 - Microfluidics is recognized as a powerful tool to perform series of experiments with high efficiency and low reagent consumption. Micromixers are known to be a very important part of the integrated microfluidic systems. The present work investigates the mixing enhancement of microfluids using a micromixer through a passive method. New type of baffles based on topology optimization are presented to augment the advection part of the mixing. Numerical simulation is carried out using Comsol Multiphysics software. The results are verified using experimental findings collected from a manufactured sample of the designed micromixer. The demonstrated geometry causes the entire mixing to take place at a short time and the length of a microchannel. The mixing quality was declined by increasing Reynolds number from Re = 0.2–5. In addition, the mixing mechanism in this range is a pure diffusion. Consequently, an increase of the Reynolds number results in lower residence time and mixing index. By increasing the Reynolds number (exceeding Re = 5), the mixing index can be improved (reaching MI = 0.98 at Re = 100). The formation of vortexes behind the designed baffles (exceeding Re = 5) is the main proof for the enhanced mixing.
AB - Microfluidics is recognized as a powerful tool to perform series of experiments with high efficiency and low reagent consumption. Micromixers are known to be a very important part of the integrated microfluidic systems. The present work investigates the mixing enhancement of microfluids using a micromixer through a passive method. New type of baffles based on topology optimization are presented to augment the advection part of the mixing. Numerical simulation is carried out using Comsol Multiphysics software. The results are verified using experimental findings collected from a manufactured sample of the designed micromixer. The demonstrated geometry causes the entire mixing to take place at a short time and the length of a microchannel. The mixing quality was declined by increasing Reynolds number from Re = 0.2–5. In addition, the mixing mechanism in this range is a pure diffusion. Consequently, an increase of the Reynolds number results in lower residence time and mixing index. By increasing the Reynolds number (exceeding Re = 5), the mixing index can be improved (reaching MI = 0.98 at Re = 100). The formation of vortexes behind the designed baffles (exceeding Re = 5) is the main proof for the enhanced mixing.
KW - Laminar flow
KW - Microfluidics
KW - Micromixer
KW - Passive method
KW - Topology optimization
UR - http://www.scopus.com/inward/record.url?scp=85088220126&partnerID=8YFLogxK
U2 - 10.1016/j.cherd.2020.07.008
DO - 10.1016/j.cherd.2020.07.008
M3 - Article
AN - SCOPUS:85088220126
SN - 0263-8762
VL - 161
SP - 187
EP - 196
JO - Chemical Engineering Research and Design
JF - Chemical Engineering Research and Design
ER -