N2 - This paper investigates the heat transfer properties of liquefied natural gas (LNG) in a corrugated plate heat exchanger and explores its application in cold energy recovery for enhanced energy efficiency. The study aims to integrate this technology into a 500 MW gas-fired power plant and a district cooling system to contribute to sustainable city development. Using computational fluid dynamics simulations and experimental validation, the heat transfer behaviour of LNG in the corrugated plate heat exchanger is examined, emphasising the significance of the gas film on the channel wall for efficient heat transfer between LNG and water/ethylene glycol. The study analyses heat exchange characteristics below and above the critical point of LNG. Below the critical point, the LNG behaves as an incompressible fluid, whereas above the critical point, the compressible supercritical state enables a substantial energy recovery and temperature rise at the outlet, highlighting the potential for cold energy recovery. The results demonstrate the effectiveness of cold energy recovery above the critical point, leading to significant energy savings and improved efficiency compared to conventional systems. Optimal operational parameters, such as the number of channels and flow rate ratios, are identified for successful cold energy recovery. This research provides valuable insights for sustainable city planning and the transition towards low-carbon energy systems, contributing to the overall goal of creating environmentally friendly and resilient urban environments.
AB - This paper investigates the heat transfer properties of liquefied natural gas (LNG) in a corrugated plate heat exchanger and explores its application in cold energy recovery for enhanced energy efficiency. The study aims to integrate this technology into a 500 MW gas-fired power plant and a district cooling system to contribute to sustainable city development. Using computational fluid dynamics simulations and experimental validation, the heat transfer behaviour of LNG in the corrugated plate heat exchanger is examined, emphasising the significance of the gas film on the channel wall for efficient heat transfer between LNG and water/ethylene glycol. The study analyses heat exchange characteristics below and above the critical point of LNG. Below the critical point, the LNG behaves as an incompressible fluid, whereas above the critical point, the compressible supercritical state enables a substantial energy recovery and temperature rise at the outlet, highlighting the potential for cold energy recovery. The results demonstrate the effectiveness of cold energy recovery above the critical point, leading to significant energy savings and improved efficiency compared to conventional systems. Optimal operational parameters, such as the number of channels and flow rate ratios, are identified for successful cold energy recovery. This research provides valuable insights for sustainable city planning and the transition towards low-carbon energy systems, contributing to the overall goal of creating environmentally friendly and resilient urban environments.
KW - cold energy recovery
KW - corrugated plate heat exchanger
KW - district cooling system (DCS)
KW - liquefied natural gas (LNG)
KW - numerical simulation
KW - sustainable cooling
UR - http://www.scopus.com/inward/record.url?scp=85175066711&partnerID=8YFLogxK
U2 - 10.3390/inventions8050121
DO - 10.3390/inventions8050121
M3 - Article
AN - SCOPUS:85175066711
SN - 2411-5134
VL - 8
JO - Inventions
JF - Inventions
IS - 5
M1 - 121
ER -