Fault Analysis and Fault-Tolerant Method of Dual Active Bridge Converter under Triple Phase Shift Control

Haochen Shi, Huiqing Wen, Jinglin Li

Research output: Chapter in Book or Report/Conference proceedingConference Proceedingpeer-review

12 Citations (Scopus)

Abstract

The open circuit fault on switches serious threat safe operation of DAB converter. In this paper, the fault phenomena of different switches during various operation condition under triple phase shift control is presented. Based on those analysis, the advanced fault diagnose which uses midpoint voltage as diagnosis criteria. It can ensure fast detect and accurate locate failure switch. After the failure switch is located, fault-tolerant is presented to maintain power transmission ability of DAB converter and ensure safe operation. Experimental result of proposed open circuit fault performance, fault diagnose method and fault-tolerant method is validated with experimental result.

Original languageEnglish
Title of host publicationICPE 2019 - ECCE Asia - 10th International Conference on Power Electronics - ECCE Asia
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages1121-1127
Number of pages7
ISBN (Electronic)9788957083130
Publication statusPublished - May 2019
Event10th International Conference on Power Electronics - ECCE Asia, ICPE 2019 - ECCE Asia - Busan, Korea, Republic of
Duration: 27 May 201930 May 2019

Publication series

NameICPE 2019 - ECCE Asia - 10th International Conference on Power Electronics - ECCE Asia

Conference

Conference10th International Conference on Power Electronics - ECCE Asia, ICPE 2019 - ECCE Asia
Country/TerritoryKorea, Republic of
CityBusan
Period27/05/1930/05/19

Keywords

  • DAB converter
  • Fault tolerant method
  • Open circuit fault
  • TPS control

Cite this