N2 - Non-destructive tests (NDTs) represent one of the solutions that aid engineers in evaluating the strength of materials. However, the results obtained using such tests are still questionable as they may be affected by different factors. One of these factors is the presence of steel reinforcement in concrete. An experimental investigation is presented in this study to investigate the effect of the single reinforcement steel bar on ultrasonic pulse velocity (UPV). Seven concrete beams, one containing no steel and the other six beams containing varying bar diameter and cover thicknesses, were tested. UPV measurements were obtained using the indirect method and then modified to eliminate the effect of the steel bar. To provide the scientific evidence to give a reliable and reasonable solution, a statistical analysis was also conducted. The results show that a large bar diameter and a small cover thickness significantly influence the measured UPV. Measured UPV with a spacing between transducers up to 500 mm can effectively be used to predict the compressive strength of concrete after the modification of the initial UPV.
AB - Non-destructive tests (NDTs) represent one of the solutions that aid engineers in evaluating the strength of materials. However, the results obtained using such tests are still questionable as they may be affected by different factors. One of these factors is the presence of steel reinforcement in concrete. An experimental investigation is presented in this study to investigate the effect of the single reinforcement steel bar on ultrasonic pulse velocity (UPV). Seven concrete beams, one containing no steel and the other six beams containing varying bar diameter and cover thicknesses, were tested. UPV measurements were obtained using the indirect method and then modified to eliminate the effect of the steel bar. To provide the scientific evidence to give a reliable and reasonable solution, a statistical analysis was also conducted. The results show that a large bar diameter and a small cover thickness significantly influence the measured UPV. Measured UPV with a spacing between transducers up to 500 mm can effectively be used to predict the compressive strength of concrete after the modification of the initial UPV.
KW - compressive strength
KW - concrete
KW - non-destructive test
KW - steel reinforcement
KW - ultrasonic pulse velocity
UR - http://www.scopus.com/inward/record.url?scp=85133608458&partnerID=8YFLogxK
U2 - 10.3390/ma15134565
DO - 10.3390/ma15134565
M3 - Article
AN - SCOPUS:85133608458
SN - 1996-1944
VL - 15
JO - Materials
JF - Materials
IS - 13
M1 - 4565
ER -