Abstract
Present study consists the development of superficial neuromast and concentrates on the fabrication method and measurement system. Biomimetic flow sensor of this study consisted of single hair cell that attached perpendicular to subtract and strain gage was used as a sensing element. Simulation and experiment were done for various flow rates 0. 1 to 0. 5 m/s. Sensitivity of the sensor was obtained as 0. 26 mV/ms-1 based on the applied flow rate and output voltage. The experiment of moving object detection have been demonstrated where it enables to detect the moving object at close range 2 cm.
Original language | English |
---|---|
Pages (from-to) | 527-532 |
Number of pages | 6 |
Journal | Indian Journal of Marine Sciences |
Volume | 41 |
Issue number | 6 |
Publication status | Published - Feb 2012 |
Externally published | Yes |
Keywords
- Biomimetic flow sensor
- Lateral line flow sensor
- Object detection
- Underwater application