Abstract
Independently controlled multimotor drives are typically realized by using a common dc link and independent sets of three-phase inverters and motors. In the case of an open-circuit fault in an inverter leg, one motor becomes single phase. To enable continued controllable operation by eliminating single phasing, the supply for the motor phase with the faulted inverter leg can be paralleled to a healthy leg of another inverter using hardware reconfiguration. Hence, the two motors are now supplied from a five-leg inverter, which has inherent voltage and current limitations. Theoretically, violating the voltage limit leads to inverter overmodulation and large torque oscillations. It is shown here that the finite-control-set model predictive control, designed to control the machines' stator flux and torque, can consider the inherent voltage limit dynamically in the control loop. Apart from preserving the independent control of the two machines, the additional constraint consideration significantly widens the operating speed ranges of the machines. In particular, it is shown that, whenever the voltage limit is entered, the controller reduces the stator flux level automatically, without requiring external flux reference change. The obtained performance is illustrated using experimental results and is also compared to the conventional two-motor field-oriented control scheme. The control concept is thus fully experimentally verified.
Original language | English |
---|---|
Article number | 6797932 |
Pages (from-to) | 6603-6614 |
Number of pages | 12 |
Journal | IEEE Transactions on Industrial Electronics |
Volume | 61 |
Issue number | 12 |
DOIs | |
Publication status | Published - 1 Dec 2014 |
Externally published | Yes |
Keywords
- Field weakening
- flux and torque control
- model predictive control
- open-circuit fault
- two-motor drive