The study of Detecting and Controlling System of Mineral Pulp Level

  • Liu Yuan*
  • , Li Zhekun
  • , Fu Junyu
  • , Wang Feng
  • *Corresponding author for this work
  • Tianjin University
  • Kunming University of Science and Technology

Research output: Chapter in Book or Report/Conference proceedingConference Proceedingpeer-review

Abstract

In this paper we established the Detecting and Controlling System of Mineral Pulp Level. It abandoned the traditional PID control method. The system adopted an advanced adaptive fuzzy PID control method, applying the Labview to built Monitoring and Controlling System in current time for flotation column, which achieved the real-time monitoring of floatation column liquid level control system and can guarantee the floatation column level in stability and suitability at the same time, together with highly automation degree, convenient operation and it can achieve the remote and local human-machine conversation.

Original languageEnglish
Title of host publication2011 IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems, CYBER 2011
Pages195-200
Number of pages6
DOIs
Publication statusPublished - 2011
Event1st Annual IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems, CYBER 2011 - Kunming, China
Duration: 20 Mar 201123 Mar 2011

Publication series

Name2011 IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems, CYBER 2011

Conference

Conference1st Annual IEEE International Conference on Cyber Technology in Automation, Control, and Intelligent Systems, CYBER 2011
Country/TerritoryChina
CityKunming
Period20/03/1123/03/11

Keywords

  • Control system
  • Floatation column
  • Fuzzy
  • Labview
  • Liquid level
  • PID