TY - JOUR
T1 - Experimental and analytical investigation of the axial load bearing capacity of TRM-confined masonry columns after exposure to elevated temperatures
AU - Yang, Pengliang
AU - Krevaikas, Theofanis
N1 - Publisher Copyright:
© The Author(s), under exclusive licence to RILEM 2026.
PY - 2026/3
Y1 - 2026/3
N2 - Purpose: This study examines the residual compressive behaviour, failure modes, and mechanical properties of textile-reinforced mortar (TRM)-confined masonry columns following exposure to elevated temperatures. Its main purpose is to investigate the temperature-dependent strength degradation and recovery, and to propose a methodology using existing analytical models (CNR, ACI, RILEM), to assess the residual axial load-bearing capacity. Methods: Two masonry types were tested: a low-strength assemblage representative of heritage structures, confined with a coated carbon fibre grid, and a higher-strength assemblage resembling modern masonry, confined with a dry carbon grid. Specimens were subjected to sustained heating at 100 °C, 200 °C, and 300 °C for 8 h. Tensile and compressive tests were conducted on fibre yarns, TRM coupons, and confined columns. Results: Results revealed a temperature-dependent strength degradation: up to 23% average reduction for low-strength masonry and 13% for high-strength masonry at temperatures below 200 °C. Remarkably, strength recovery was observed at 300 °C, with gains of up to 30% and 8%, respectively. Three existing analytical models were adapted via a proposed methodology to incorporate temperature-dependent degradation laws, yielding preliminary predictions that align with experimental trends. Conclusion: Findings emphasize the complex thermo-mechanical interaction in TRM-confined masonry, especially the strength recovery at 300 °C, and the necessity for further investigation needed to refine existing analytical models to account for the thermal effects.
AB - Purpose: This study examines the residual compressive behaviour, failure modes, and mechanical properties of textile-reinforced mortar (TRM)-confined masonry columns following exposure to elevated temperatures. Its main purpose is to investigate the temperature-dependent strength degradation and recovery, and to propose a methodology using existing analytical models (CNR, ACI, RILEM), to assess the residual axial load-bearing capacity. Methods: Two masonry types were tested: a low-strength assemblage representative of heritage structures, confined with a coated carbon fibre grid, and a higher-strength assemblage resembling modern masonry, confined with a dry carbon grid. Specimens were subjected to sustained heating at 100 °C, 200 °C, and 300 °C for 8 h. Tensile and compressive tests were conducted on fibre yarns, TRM coupons, and confined columns. Results: Results revealed a temperature-dependent strength degradation: up to 23% average reduction for low-strength masonry and 13% for high-strength masonry at temperatures below 200 °C. Remarkably, strength recovery was observed at 300 °C, with gains of up to 30% and 8%, respectively. Three existing analytical models were adapted via a proposed methodology to incorporate temperature-dependent degradation laws, yielding preliminary predictions that align with experimental trends. Conclusion: Findings emphasize the complex thermo-mechanical interaction in TRM-confined masonry, especially the strength recovery at 300 °C, and the necessity for further investigation needed to refine existing analytical models to account for the thermal effects.
KW - Analytical modelling
KW - Carbon TRM
KW - Compressive strength
KW - Masonry column confinement
KW - Post-heated behaviour
UR - https://www.scopus.com/pages/publications/105029933393
U2 - 10.1617/s11527-026-02959-z
DO - 10.1617/s11527-026-02959-z
M3 - Article
AN - SCOPUS:105029933393
SN - 1359-5997
VL - 59
JO - Materials and Structures/Materiaux et Constructions
JF - Materials and Structures/Materiaux et Constructions
IS - 2
M1 - 102
ER -