Cyclic performance of corroded RC columns repaired with textile-reinforced mortar (TRM) and organic corrosion inhibitors

  • Xi'an Jiaotong-Liverpool University
  • Research Institute for Sustainable Materials and Environment
  • University of Liverpool

Research output: Contribution to journal › Article › peer-review

Abstract

Reinforcement corrosion significantly compromises the performance of reinforced concrete (RC) columns, highlighting the need for repair strategies that both restore strength and limit further deterioration. This study evaluated the effectiveness of integrating organic corrosion inhibitors (OCIs) with textile-reinforced mortar (TRM) to repair corrosion-damaged RC columns under cyclic loading, focusing on both mechanical and durability performance. Seven large-scale low-strength concrete columns representative of older, corrosion-prone construction were tested, including corroded and uncorroded specimens with and without TRM repair. Two reinforcement corrosion levels (10% and 30% mass loss) were considered, and two TRM-repaired specimens were subjected to extended chloride dry–wet cycling before testing. All columns were tested under a constant axial load corresponding to an axial compression ratio of 0.10 and subjected to cyclic lateral loading. Corrosion noticeably reduced strength, deformation capacity, stiffness, and energy dissipation, with the 30% corroded specimen experiencing severe degradation. TRM repair substantially improved cyclic behaviour, producing fuller hysteretic loops and enhanced post-yield deformation response. The TRM-repaired column with a corrosion level of 10% achieved a 58% increase in peak load and a 153% increase in cumulative energy dissipation relative to the control specimen. Half-cell potential measurements showed that the OCI-modified TRM confinement effectively reduced corrosion activity, with repaired specimens maintaining lower corrosion risks even after 300 chloride cycles. Overall, integrating OCI with TRM confinement provides a durable and sustainable repair solution, enhancing both the seismic performance and corrosion resistance of deteriorated RC columns.

Original languageEnglish
Article number116683
JournalJournal of Building Engineering
Volume128
DOIs
Publication statusPublished - 15 Jun 2026

Keywords

  • Concrete columns
  • Corrosion damage
  • Corrosion inhibitors
  • Durability
  • Seismic performance
  • Structural repair
  • Textile-reinforced mortar (TRM)