Skip to main navigation Skip to search Skip to main content

A non-contact wearable device for monitoring epidermal molecular flux

  • Jaeho Shin
  • , Joseph Woojin Song
  • , Matthew Thomas Flavin
  • , Seunghee Cho
  • , Shupeng Li
  • , Ansen Tan
  • , Kyung Rok Pyun
  • , Aaron G. Huang
  • , Huifeng Wang
  • , Seongmin Jeong
  • , Kenneth E. Madsen
  • , Jacob Trueb
  • , Mirae Kim
  • , Katelynn Nguyen
  • , Angela Yang
  • , Yaching Hsu
  • , Winnie Sung
  • , Jiwon Lee
  • , Sooyeol Phyo
  • , Ji-Hoon Kim
  • Anthony Banks, Jan-Kai Chang, Amy S. Paller, Yonggang Huang, Guillermo A. Ameer, John A. Rogers*
*Corresponding author for this work
  • Northwestern University

Research output: Contribution to journalArticlepeer-review

46 Citations (Scopus)

Abstract

Existing wearable technologies rely on physical coupling to the body to establish optical1,2, fluidic3,4, thermal5,6 and/or mechanical7,8 measurement interfaces. Here we present a class of wearable device platforms that instead relies on physical decoupling to define an enclosed chamber immediately adjacent to the skin surface. Streams of vapourized molecular substances that pass out of or into the skin alter the properties of the microclimate defined in this chamber in ways that can be precisely quantified using an integrated collection of wireless sensors. A programmable, bistable valve dynamically controls access to the surrounding environment, thereby creating a transient response that can be quantitatively related to the inward and outward fluxes of the targeted species by analysing the time-dependent readings from the sensors. The systems reported here offer unique capabilities in measuring the flux of water vapour, volatile organic compounds and carbon dioxide from various locations on the body, each with distinct relevance to clinical care and/or exposure to hazardous vapours. Studies of healing processes associated with dermal wounds in models of healthy and diabetic mice and of responses in models using infected wounds reveal characteristic flux variations that provide important insights, particularly in scenarios in which the non-contact operation of the devices avoids potential damage to fragile tissues.
Original languageEnglish
Pages (from-to)375-383
Number of pages9
JournalNature
Volume640
Issue number8058
DOIs
Publication statusPublished - 9 Apr 2025
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'A non-contact wearable device for monitoring epidermal molecular flux'. Together they form a unique fingerprint.

Cite this